What was found
FWD CARGO COMPT. CROSS SLIDE DOOR AREA L-35L CRACKED 1.000 STA 300.000-310.000 MAJOR REPAIR. PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG. 1B. REMOVED FASTENERS IAW SRM 51-1-20D PG. 21. PERFORMED STOP HOLE IAW SRM 53-2-0 FIG. 1B SHEET 3. PERFORMED NDT INSP IAW DC8 NDT SPM PART 06-10-01-001. FABRICATED ANGLE DOUBLER IAW SRM 53-2-0 FIG. 1B SHEET 3, SRM 53-4-1 FIG. 28. CLEANED, TREATED AND PRIMED AREA AND ANGLE DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG. 9. INSTALLED ANGLE DOUBLER IAW SRM 53-2-0 FIG. 1B SHEET 3, SRM 51-1-220D PG. 9. TORQUED IAW SRM 51-3-1 PG. 2A.