What was found
WORN, NO 2 ENG COWLING LANDING - FROM 1 O'CLOCK TO 11 O'CLOCK POSITION. REMOVED DAMAGED SECTION OF CHORD, FORMED AND DRILLED REPAIR ANGLES FOR SPLICE. DRILLED NEW SECTION OF CHORD OK TO INSTALL. INSTALLED LT SPLICE. COMPLETED INSTALLATION OF RING AND RT SPLICE. REPAIRED PER M/M 53-11-0. OK TO INSTALL LOWER CLOSE OUT WEB 5 O'CLOCK TO 7 O'CLOCK.