What was found
WHEN GEAR HANDLE WAS PUT IN THE DOWN POSITION, NOTHING HAPPENED. (M2B) - PERFORMED FUNCTIONAL TEST OF EXTENSION AND RETRACTION OF LANDING GEARS AND DOORS, LANDING SAFETIES, AND MAIN DOOR PROX SWITCHES AND GEAR ACTUATOR PROX SWITCHES, AND DOOR UP LOCK AND GEAR UPLOCK. NO DEFECTS NOTED. WORK DONE IN ACCORDANCE WITH F2000 MM 32-300, 31-400, AND 32-605.