What was found
AFTER TAKEOFF RECEIVED ACM OVERHEAT INDICATION WITH RT BLEED AIR AND RT ITT (RED FLAG) INDICATION, ALSO HAD A ODOR OF SOMETHING BURNED COMING OUT OF THE VENTS ITT WAS APPROXIMATELY BETWEEN 750-760 DEG F FOR 4-5 SECONDS. [07-09-07] REMOVED AND REPLACED THE RT FLOW CONTROL VALVE W/A OVERHAULED UNIT AS PER THE CE560XL AMM CHAPTER 21-11-00. OPS CHECKS GOOD. LEAK CHECK SATISFACTORY