Service difficulty report · Controller · Cessna 560CESSNA

Difficulty date
December 20, 2007
Submitted
January 7, 2008
Operation
Air carrier
Aircraft
N335QS
Make and model
Cessna 560CESSNA
Aircraft serial
5600335
Aircraft time
11,039 hours, 8,871 cycles
Engine
Pwa JT15D5
Part
Controller
Part number
99120856
Part serial
9AV134
Condition
Inoperative
Location
Windshield Heat
Part time
4,007 hours, 3,292 cycles
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WINDSHIELD OVERHEAT ANNUNCIATOR ILLUMINATED WITH WINDSHIELD HEAT SELECTED ON IN THE LOW POSITION. RAN CHECKLIST AND SELECTED OFF. CONDITION OCCURED ABOUT 30 TO 60 SECONDS AFTER SELECTING ON. HOT BURNING ODOR WAS PRESENT.KSPI-KLAL. TROUBLESHOT PROBLEM DOWN TO A BLOWN FUSE INSIDE OF WINDSHIELD TEMP CONTROLLER. REMOVED CONTROLLER P/N 9912085-6 S/N 9AV134 AND INSTALLED NEW CONTROLLER PIN 9912085-6 S/N 8BC167 IAW CESSNA CITATION 560 AMM SECTION 30-41-02. OPS CHECK SATISFACTORY.