What was found
AFTER TAKEOFF, THE GEAR UNSAFE LIGHT ILLUMINATES AFTER THE GEAR HANDLE IS PLACED IN THE UP POSITION. THE HYD PRESS AND STAB MISCOMPARE ANNUNCIATOR ALSO ILLUMINATE. PULLING THE HYD CONT CB, DOES NOT DROP ANY LANDING GEAR ASSEMBLIES OR EXTINGUISH THE UNLOCK LIGHT. TROUBLESHOT TO THE RT UPLOCK ACTUATOR, SPRING TOO WEAK TO ENGAGE HOOK FULLY. REMOVED AND REPLACED SPRING. OPS CHECK GOOD IAW MM CH 32-30-05