What was found
YELLOW ELE"AIL" TRIM ON MAIN MASTER WARNING PANEL ILLUMINATED IN FLIGHT WHEN ELEVATOR TRIM WHEEL POSITION OUTSIDE OF TAKEOFF RANGE. FOUND THAT WIRING WAS TERMINATED WITH SIZE 8 LUGS. TERMINAL POST IS A SIZE 6 STUD. RETERMINATED LT WOW WIRING WIRE FOR WIRE WITH THE PROPER SIZE TERMINAL LUG. APPLIED ACFT POWER AND PERFORMED THE ELEVATOR OUT OF TRIM ANNUNCIATOR FUNCTIONAL TEST-CHECKED GOOD WITH NO DEFECTS NOTED. WORK PERFORMED IAW MM. CHAPTER 27-30-00. PERFORMED THE AILERON OUT OF TRIM ANNUNCIATOR FUNCTIONAL TEST-CHECKED GOOD WITH NO DEFECTS.