What was found
ON DEPARTURE WHEN GEAR HANDLE SELECTED TO UP, THERE WAS A SIGNIFICANT NOSE GEAR RETRACTION DELAY. THE NOSE GEAR GREEN DOWN INDICATOR REMAINED ILLUMINATED AND RED UNSAFE LIGHT REMAINED ILLUMINATED FOR 30-40 SECONDS AFTER GEAR RETRACTION BEFORE IT EVENTUALLY RETRACTED. THE MAIN GEAR GREEN LIGHTS EXTINGUISHED NORMALLY. JACKED ACFT AND CYCLED GEAR REPEATEDLY. NO DEFECTS WERE NOTED. ALL INDICATIONS NORMAL. INSPECTED WIRING AND CONNECTORS IN GEAR WHEEL WELL WITH NO DISCREPANCIES FOUND. FROZE DOWNLOCK SWITCH AND CYCLED GEAR NUMEROUS TIMES. UNABLE TO DUPLICATE DISCREPANCY. WORKED REF MM 32-30-00.