Service difficulty report · Controller · Cessna 560CESSNA

Difficulty date
May 31, 2014
Submitted
July 7, 2014
Operation
Air carrier
Aircraft
N827QS
Make and model
Cessna 560CESSNA
Aircraft serial
5600801
Aircraft time
3,847 hours, 3,083 cycles
Part
Controller
Part number
1E581
Part serial
8BD150
Condition
Failed
Location
Windsheild Heat
Part time
3,847 hours, 3,083 cycles
Stage of operation
DE
How discovered
O
Nature of condition
J, B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WINDSHIELD ANTI-ICE OVERHEATED IN FLIGHT AT -14 C RAT. BURNING ODOR IS ALSO ACCOMPANYING THE WINDSHIELD OVERHEAT LIGHT & MASTER CAUTION. DURING TESTING AND TROUBLESHOOTING FOUND TEMP CONTROLLER NOT MODULATING AT CORRECT TEMPERATURES. REMOVED AND REPLACED TEMPERATURE CONTROLLER IAW AMM 30-41-02. REMOVED AND REPLACED TEMPERATURE SENSOR IAW AMM 30-41-02. REMOVED & REPLACED TEMPERATURE BULB IAW AMM 30-41-02. COMPLIED WITH FINAL OPERATIONAL CHECK AND TEMP CONTROLLER IS OPERATING GOOD WITH MODULATING RAM AIR CORRECTLY DURING ENGINE RUN. WORK DONE IAW MM 30-41-00, MM 30-41-02 MM 30-41-03.