What was found
MAIN EXIT SIGN/LIGHT: MAIN EXIT SIGN LIGHT, BOTH FLOOR EXIT SIGN LIGHTS ADJACENT TO THE MAIN DOOR, AND EMERGENCY EXIT LIGHT UNDER SEAT 10 ALL WILL NOT EXTINGUISH. // SIGNOFF// ON ENTRY OF AIRCRAFT FOUND FWD EMERGENCY LIGHTS ILLUMINATED. ALL THESE UGHTS ARE POWERED FROM #1 EMERGENCY BATTERY, REMOVED R/H CENTER PEDESTAL PANEL TO GAIN ACCESS TO #1 EMERGENCY LIGHT G SWITCH. RESET INERTIA SWITCH AND LIGHTS WENT OUT IMMEDLATELY, PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHTING SYSTEM. OPS CHECK GOOD. ALL WORK PERFORMED IAW CESSNA 680A AMM 33-50-00. NO DEFECTS NOTED AT THIS TIME.