What was found
DESCRIPTION: DURING THE STRUCTURAL INSPECTION PER WORK CARD Nº: 553006-01-2-001 MPD, IT WAS FOUND AT EMPENNAGE RUDDER HINGE #7 BEARING WITH PLAY.
CORRECTIVE ACTION: REPLACED FORK AND END FITTING AT HINGE ARM BR7 IAW A319-SRM TASK 55-36-42-300-008.
SEE COOPESA WORK ORDER A1M116 3-17