What was found
DURING ALLEGIANT INSPECTION PER WORK CARD A32X-53-260-002, UPPER FUSELAGE AFT PAX CABIN/CREW ENTRY DOOR FR66 RHS DOOR STOP FITTING # 1 LOWER I/B HOLE WITH CRACK INDICATION WAS FOUND.PERFORMED REPAIR STOP FITTING HOLES OF RHS AFT DOOR FR 66 FREEZE PLUG AND OVERSIZED BOLT INSTALLATION FITTING # 1 IAW A319 SRM TASK 53-41-12-300-010 PARAG 2A REV 150 AND TASK 53-41-12-300-008 FIG 002 AND FIG 003 REV 150.THIS REPAIR IS CATEGORIZED AS MAJOR.THIS REPAIR IS DOCUMENTED UNDER COOPESA JOB A1Q170 ITEM 2-40.