What was found
ON CLIMBOUT NR 1 GENERATOR TRIPPED VOLTS AND FREQS WERE 0 AFTER RESETTING FR. DISCONNECTED CSD PER ABNORMALS, AIR TURNBACK TO (CLT). REMOVED AND REPLACED NR 1 BUS PROTECTION PANEL, OPS CHECK OK PER M/M 24-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON CLIMBOUT NR 1 GENERATOR TRIPPED VOLTS AND FREQS WERE 0 AFTER RESETTING FR. DISCONNECTED CSD PER ABNORMALS, AIR TURNBACK TO (CLT). REMOVED AND REPLACED NR 1 BUS PROTECTION PANEL, OPS CHECK OK PER M/M 24-20-01.