As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NUMBER 1 STBY PUMP HYD HOT LIGHT ILLUMINATED. WHEN NR 1 STBY PUMP SELECTED TO NORM IN FIGHT, HYD PRESS GRADUALLY DECREASED. WHEN PUMP IS CYCLED, PRESS ONLY INCREASES TO APPROX 800 PSI. NR 1 STBY PRESS INCREASED TO 2700 WHEN FLAPS SELECTED FOR LANDING WITH SWITCH IN NORM. R & R NR 1 STBY HYD PUMP. OPERATIONS & LEAKS CHECKED GOOD IAW MM 29-11-17.