What was found
MAIN CARGO COMPARTMENT FLOORBEAM UPPER TEE HAS CORROSION BS 377 BLENED AREA IAW SRM 51-10-01. FOUND MUITIABLE AREA OUT OF LIMITS , EXCEEDS MAX OF 10% OF ORIG MAT IAW SRM 53-00-51 FIGURE 101 DETAIL III . REMOVED AND REPLACED UPPER TEE IAW SRM 51-10-01. INSTALLED REPAIR ANGLES STRAPS AND TEE IAW SRM 51-40-02.. REPAIR ANGLES , TRAVELER T10/854157, REPAIR STRAPS TRAVELER T10/ 854160 , MAJOR REPAIR.