What was found
NR 5 L/E SLAT UPPER SURFACE, T/E WEDGE, BETWEEN INBD TRACK AND MID-TRACK HAS A TEMP. REPAIR OF A DENT. (CURRENT SRM REQUIRES PERM. REPAIR AT C-CHECK) REPAIRED NR5 SLAT IAW SRM 57-43-02, REPAIR NR1. FINAL REPAIR DIMENSION IS 3" DIAMETER. THE SLAT ASSY P/N IS : 144N3002-65, S/N: A1-0204. REPAIR IS LOCATED AT APPROX. 36" FROM INBD END. REF EA F-5740-146243 FOR TRACKING. MAJOR REPAIR.