What was found
EXTENDING FLAPS 35 FOR LANDING, RECEIVED A LEVEL 2 SLAT DISAGREE AND FLAP DISAGREE ALERTS. TRIED SECOND TIME. ON SECOND ATTEMPT, FLAPS AND SLATS EXTENDED NORMAL WITH NORMAL LANDING, INBOUND PILOT OPS CHECKED THE FLAP/SLAT SYS WITH NORMAL OPS ON SECOND TIME. PERFORMED FLAPS ADJUSTMENT AND TEST IAW MM 27-50-00-5-1, ITEM D FLAP HYD ACTUATION SYS OPERATED NORMAL. FCC SENSOR READOUT WITHIN TOLERANCE OF -2 DEGREES. ACFT OK FOR SERVICE.