What was found
RTO AT 110KTS FOR, ENG 3 EXCEEDANCE, LVL 1 ALERT. NR 3 EGT SHOWED YELLOW, 1011, FOR EXCEEDANCE, ESTIMATE EXCEEDANCE WAS MOMENTARY. PULLED UP VIA NR 3 ENG EXCEEDANCES. THE ACARS EXCEEDENCE SHOWS IT WAS AN EGT INDICATION PROBLEM. R & R NR 3 ENG TOP LT EGT THERMOCOUPLE HARNESS & PROBES ASSEMBLY. WORK ACCOMPLISHED IAW MM 77-21-01-2. R & R NR 3 ENG RT FWD THERMOCOUPLE LEAD IAW AMM 77-21-02-2. R & R TOP RIGHT, BOTTOM RIGHT & BOTTOM LEFT EGT HARNESS IAW AMM 77-21-01-2. R & R AFT EGT HARNESS IAW AMM 77-21-01-2. PERFORMED STAIC RUN IAW JRH WITH NO DEFECTS NOTED. PERFORMED HI POWER RUN UP FOR NR 3 ENG IAW JRH. ALL PARAMETERS WITHIN LIMITS OUTLINED IN JRH.