What was found
PDIS 560 27-80 4198 06NOV18 MEM FACT U LOGPAGES:2954473 SLAT DISAG WHEN FLAPS 35 SELECTED. WENT AROUND AND DID EXT/ 22 LANDING PER QRH. SHGN 06NOV18 09:01 MEM U T/S IN REF TO MD10 FIM 27-80-00-2. NO SLAT DISAG INDICATION SHOWN. INTERROGATED PSEU, FCC1 AND FCC2. NO FAULTS FOUND. CYCLED FLAPS AND SLATS SEVERAL TIMES WITH NO FAULTS FOUND. PERFORMED PRECAUTIONARY R-T-S OF PSEU IN REF TO MD10 AMM 31-71-01-2. NO FAULTS FOUND. REQUIRES MORE T/S. SHGN 06NOV18 10:50 MEM U PERFORMED RTS REF AMM 22-00-00-5-0. FCC 1 & FCC 2 SLATS RTS PASSED. OK FOR SERVICE. FACT 06NOV18 10:58 MEM U FACT. T/S IN REF TO MD10 FIM 27-80-00-2. NO SLAT DISAG INDICATION SHOWN. INTERROGATED PSEU, FCC1 AND FCC2. NO FAULTS FOUND. CYCLED FLAPS AND SLATS SEVERAL TIMES WITH NO FAULTS FOUND. PERFORMED PRECAUTIONARY R-T-S OF PSEU IN REF TO MD10 AMM 31-71-01-2. NO FAULTS FOUND. REQUIRES MORE T/S. SHGN 06NOV18 10:50 MEM U PERFORMED RTS REF AMM 22-00-00-5-0. FCC 1 & FCC 2 SLATS RTS PASSED. OK FOR SERVICE. FACT 06NOV18 10:58 MEM U FACT.