What was found
UPON GEAR EXTENSION, NOSE GEAR UNSAFE LIGHT ILLUMINATED. CREW USED THE ALT METHOD, MANUALLY EXTENDING GEARS). ACCOMPLISHED BITE CHECK, NO FAULTS NOTED. ACFT TO BE MAINTENANCE FERRIED BACK TO HOME BASE, IN, GEAR DOWN CONFIGURATION, TO BE JACKED AND OPS CHECKED IAW AMM. REMOVED NOSE GEAR BUNGEE CYLINDER IAW AMM 32-35-02, 17267. INSTALLED NOSE GEAR BUNGEE CYLINDER IAW AMM 32-35-02-400-801, OPS CHECK LEAK CHECK GOOD. REMOVED 3 GEAR PINS. OK FOR SERVICE.