What was found
ETOPS - BTB AIR ENG HI TEMP AFTER COMPLETING PROCEDURE FOR MEL 36-11-07B ON TAXI OUT. REFERENCE DEFERRAL 207735 FOR REMOVAL AND REPLACEMENT OF #2 HP VALVE ON LP 946395-1. REMOVED AND REPLACED #2 ENG HPV PER AMM 36-11-51. CONDITION SAME. PERFORMED WIRING CHECK BETWEEN 4000HA2 TO BMC 1 AND 2. COUNTINTY CHECK GOOD. NO SHORT TO GROUND. PER TSM 36-11-00-810-974-A. RE-SECURED SENSE LINE FOR HPV #2 ENGINE, ACCOMPLISHED #1 AND #2 ENGINE IDLE RUB TEST #3 AMM 71-00-00 AND BLEED SYSTEM TEST AMM 6-11-00 NO DEFECT NOTED- PLACARD REMOVED - CLEARED MIC SHEET