SDR HEEA111153

Service difficulty report · Connector · Urocop EC135P2

Difficulty date
September 19, 2006
Submitted
September 25, 2006
Operation
Air carrier
Aircraft
N309PH
Make and model
Urocop EC135P2
Aircraft serial
0403
Aircraft time
424 hours
Engine
Pwa PW206B
Part
Connector
Condition
Contaminated
Location
Fadec
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE FLIGHT, WHILE TRANSPORTING AN INTERFACILITY PATIENT, THE NR 2 FADEC MINOR CAUTION INTERMITTENTLY ILLUMINATED. DISCONNECTED THE NP, TORQUE, AND PMA CONNECTORS AND THEY WERE ALL WET WITH WATER. CLEANED AND DRIED THEM OFF AND APPLIED STABILANT 22 TO ALL OF THEM AND THAT FIXED THE PROBLEM.

More about the Urocop EC 135 P2