What was found
CORROSION FOUND AT APU DOOR STATION 1885 8 O CLOCK POSITION.REMOVED FASTENERS AND DAMAGE TRIM OUT IS 3.50€? X 3.25€?. COMPLETED PARAGRAPHS 1 THRU 4 OF SRM 53-80-01-2 REPAIR 3. COMPLETED REPAIR IAW EO-89978-REQ1
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND AT APU DOOR STATION 1885 8 O CLOCK POSITION.REMOVED FASTENERS AND DAMAGE TRIM OUT IS 3.50€? X 3.25€?. COMPLETED PARAGRAPHS 1 THRU 4 OF SRM 53-80-01-2 REPAIR 3. COMPLETED REPAIR IAW EO-89978-REQ1