What was found
**SDR FILED OPEN** STR, DURING DECAY FUSELAGE OP CHECK, FOUND R1 DOOR UPPR AFT CORNER BEND, 52-10 REQUEST ENGINEERING TO PROPER CLASSIFICATION OF MAJOR OR MINOR I.A.W UPS GMM-MTX REV 7B 03-43 DUE TO REPAIR ON PRIMARY STRUCTURE ON RH FWD PASSENGER DOOR (R1) AT STA YNBD=+8.5 - YNPD=+17.3 BETWEEN #8 BEAM & UPPER EDGE OF DOOR .