What was found
DURING TAKEOFF, THE LANDING GEAR CIRCUIT BREAKER TRIPPED WHEN THE FLIGHT CREW ATTEMPTED TO STOW THE LANDING GEAR. MAINTENANCE PERFORMED THREE SUCCESSFUL LANDING GEAR SWINGS, CONDUCTED AN INSPECTION ON ALL ASSOCIATED WIRING, CHECKED THE SERVICING VALVE AND MICROSWITCH, AND THE E235 SENSOR CHECKED OK. MAINTENANCE THEN PERFORMED ANOTHER SIX-LANDING GEAR EXTENSION AND RETRACTION FUNCTIONAL CHECKS. ALL CHECKS WERE SUCCESSFUL. NO DEFECTS WERE DISCOVERED DURING THE TROUBLESHOOTING PROCESS.