SDR MALA000769

Service difficulty report · Isolation Valve · Bac AVRO146RJ85A

Difficulty date
December 24, 2000
Submitted
January 12, 2001
Operation
Air carrier
Aircraft
N535XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2371
Part
Isolation Valve
Part number
HP94240055
Part serial
SNON0243
Condition
Malfunctioned
Location
Lt Mlg
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT MLG WOULD NOT RETRACT AFTER TAKEOFF. FLIGHT DIVERTED TO CVG. ON TAKEOFF OUT OF TYS THE LT MAIN LANDING GEAR WOULD NOT RETRACT. CYCLED GEAR DOWN AND UP 2 ADDITIONAL TIMES, NO EFFECT. LT GEAR RED AND GEAR HANDLE WERE ILLUMINATED. VERIFIED BY AC YAW TO BE EXTENDED. EACH TIME IT WAS CYCLED IT WAS INDICATING DOWN AND LOCKED. MAINTENANCE TROUBLESHOT RETRACTION PROBLEM FOUND RETRACTION BRAKE ISOLATION VALVE BAD. REPLACED ISOLATION VALVE (P/N HP94240055) (S/N ON/ 0243), IAW 32-31-30 OF AMM, SWUNG GEAR 12 TIMES. NO FAULT FOUND. OPS CHECK GOOD.