What was found
ON CLIMBOUT DURING CLIMB EICAS LE SLAT ASYM LEADING EDGE LIGHT ON. QRH EXECUTED PER PROCEDURE. T/S REPLACED 5284 SENSOR IAW AMM 27-88-01, SPEU ADN FSEU OPS CHECK OK
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON CLIMBOUT DURING CLIMB EICAS LE SLAT ASYM LEADING EDGE LIGHT ON. QRH EXECUTED PER PROCEDURE. T/S REPLACED 5284 SENSOR IAW AMM 27-88-01, SPEU ADN FSEU OPS CHECK OK