What was found
FLAP DISAGREE INFLIGHT. QRH PROCEDURE PERFORMED. REMOVED FLAP POSITION INDICATOR CONNECTOR PLUG, CLEANED & RE-INSTALLED. PERFORMED T/E OPS TEST IAW AMM 27-51-00, PG 501. SYSTEM CHECKS SERVICEABLE. INDICATION SYS RET FOR CONTINUED SERVICE.