What was found
WHILE RETURNING TO THE BASE, THE PILOT REPORTED AN ELECTRICAL SMELL IN THE COCKPIT AND SAW A SLIGHT AMOUNT OF SMOKE FWD OF INSTRUMENT PANEL. ONCE ON THE GROUND, THE MECHANIC ARRIVED TO TROUBLESHOOT THE CAUSE OF THIS SMELL AND FOUND THE AVIONICS COOLING FAN ON THE RH SIDE OF THE INSTRUMENT PANEL WAS FROZEN, AND NOT SPINNING. THE MECHANIC WAS ABLE TO CONFIRM AN ELECTRICAL ODOR COMING FROM THIS FAN ASSEMBLY SIMILAR TO THAT WHICH WAS REPORTED BY THE PILOT. *** THIS AIRCRAFT REMAINS OOS AT THE TIME OF THIS SUBMISSION AWAITING A REPLACEMENT AVIONICS COOLING FAN TO ARRIVE. *** SUPPLEMENTAL INFORMATION: AIRCRAFT SERIAL NUMBER IN SECTION THREE ENTERED INCORRECTLY ON INITIAL SUBMISSION. N407NA IS REFERENCED TO BH407 S/N 53592.