Service difficulty report · Bleed Valve · Pilats PC1247

Difficulty date
February 27, 2025
Submitted
February 27, 2025
Operation
Air carrier
Aircraft
N895CR
Make and model
Pilats PC1247
Aircraft serial
831
Aircraft time
8,709 hours, 7,413 cycles
Part
Bleed Valve
Part number
312353201
Part serial
AHX000961
Condition
Malfunctioned
Location
Engine
Stage of operation
CL
How discovered
O
Nature of condition
R
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

UPON DEPARTURE, SET MY POWER TO ROUGHLY 34.5 TORQUE & AFTER ROTATION, ATTEMPTED TO ADD MORE POWER. WHEN ADDED MORE POWER NOTHING HAPPENED & TORQUE STAYED AROUND 34.5 AND THE ITT STAYED AROUND 680. PLACED PCL FULL FORWARD AND POWER NEVER INCREASED. AT THAT TIME IINCREASED RATE OF CLIMB & LET ATC KNOW WAS GOING TO RETURN TO AIRPORT. HAD SUFFICIENT ALTITUDE AND PREPARED FOR AN EMERGENCY IF NECESSARY. LANDED WITH OUT ANY ISSUES & MX WAS IMMEDIATELY CONTACTED ABOUT THE REDUCED POWER. REMOVED AND INSTALLED NEW P3 AIR FILTER, REMOVED AND INSTALLED NEW COMPRESSOR BLEED VALVE,