Service difficulty report · Blower · Bolkms BK117C2

Difficulty date
August 21, 2024
Submitted
August 21, 2024
Operation
General aviation
Filed by
QR9R369D
M1 Support Services
Make and model
Bolkms BK117C2
Aircraft serial
10721699417
Aircraft time
4,839 hours
Part
Blower
Part number
S6222EC1
Condition
Inoperative
Location
Evap Sys
Stage of operation
IN
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFT EVAP BLOWER MOTOR INOP (READS 28VDC INPUT). PER VENDOR, REPLACEMENT BLOWER ASSEMBLY IS NOT AVAILABLE BECAUSE THEY'RE AWAITING FAA CERTIFICATION ON UPGRADED MODEL. THIS HAS BEEN AN ONGOING ISSUE FOR APPROXIMATELY EIGHT MONTHS.