What was found
FIRE SYS FAULT STATUS MSG INTERMITTENTLY COMES ON. PLACED ON MEL 26-00-1. 11/29 CLEARED BY: INSPECTED & FOUND NR2 ENG FIRE LOOP "A" FIRE SENSOR LINK HARNESS NR2 (LOCATED AT LOWER SIDE OF ENG) CHAFED. R & R FIRE SENSOR LINK NR2 IAW AMM TASKS 26-11-09-000-802-A01 STEPS 1 THRU 3,4.B (STEPS 4.A & C N/A), & 26-11-09-400-802-A01 STEPS 1. THUR 3 (STEPS 4.A & C N/A), 4B THRU 5. FIRE SYS OP'S CHECKS ARE GOOD. RETURNED TO SERVICE.