What was found
THERE IS A 1 X .100 DENT 4.5 FORWARD OF THE RIGHTHAND CORNER OF THE 41A DOOR OPENING. REPAIRED IAW FOKKER SRM 53-02-02, FIGURE 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THERE IS A 1 X .100 DENT 4.5 FORWARD OF THE RIGHTHAND CORNER OF THE 41A DOOR OPENING. REPAIRED IAW FOKKER SRM 53-02-02, FIGURE 1.