Service difficulty report · Smoke Detector · Cndair CL6002D24

Difficulty date
October 18, 2017
Submitted
October 20, 2017
Operation
Air carrier
Aircraft
N294PQ
Make and model
Cndair CL6002D24
Aircraft serial
15294
Aircraft time
9,794 hours, 6,603 cycles
Part
Smoke Detector
Condition
False Activation
Location
Aft Lavatory
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE AT 34000 FT, A SMOKE AFT LAV WARNING APPEARED FOR 5 SECONDS WITH AURAL WARNING. FA INSPECTED THE AFT LAV AND FOUND NO SIGNS OF SMOKE OR FIRE. FIRE SYS FAULT APPEARED INTERMITTENT DURING REMAINDER OF FLIGHT. REMOVED AND REPLACED THE AFT LAVATORY SMOKE DETECTOR IAW AMM 26-16-01. PERFORMED AN OPS TEST OF THE LAV SMOKE DETECTOR AND WAS SATISFATORILY IAW AMM 26-16-00. NO DISCREPANCIES NOTED AT THIS TIME.