What was found
SHORTLY AFTER TAKEOFF, RECEIVED A BRAKE OVHT WARNING MESSAGE. COMPLETED QRH,TEMPERATURE SPIKED AGAIN. RECEIVED BRAKE OVHT WARNING AGAIN. COORDINATED WITH MOC AND DISPATCH. AIR RETURN TO RDU. DEFERRED LHIB BTMS (TEMP SENSOR) IAW MEL 32-46-1D. PLACARD INSTALLED, MOC # NOTIFIED 101954, MM02 UPDATED, MX PROCEDURES C/W. R & R BRAKE TEMP SENSOR IAW AMM 32-46-01, TOOK RESISTANCE VALUES FROM A165P1 PIN 59 AND PIN 58 GOT 68.1 OHMS. MEL REMAINS OPEN. REMOVED AND REPLACED INBORAD HARNESS ASSY FOR MLG IAW AMM 36-61-05 OPS CHECKS GOOD MMO2 UPDATED PLACARD REMOVED MOC NOTIFIED 95974 MX PROCEDURES RESTORED