What was found
ON SHORT FINAL APPROX 1000 FEET MOMENTARY FIXED PITCH, TRIM OPERATIVE. ELEVATOR FELT JAMMED THEN RELEASED & OPERATED NORMALLY. R & R ELEVATOR SERVO IAW AMM 22-11-24. OPERATIONS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON SHORT FINAL APPROX 1000 FEET MOMENTARY FIXED PITCH, TRIM OPERATIVE. ELEVATOR FELT JAMMED THEN RELEASED & OPERATED NORMALLY. R & R ELEVATOR SERVO IAW AMM 22-11-24. OPERATIONS CHECKED GOOD.