What was found
L WINDOW HEAT CAUTION MSG AT FL260-C/A-RESETED L/H WINDOW C.B. PERFORMED WINDOW TEMP CONTROLLER OPERATIONAL TEST & FOUND WORKING PROPERLY NO DEFECTTS NOTED AT THIS TIME IAW CRJ MM 30-41-06
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L WINDOW HEAT CAUTION MSG AT FL260-C/A-RESETED L/H WINDOW C.B. PERFORMED WINDOW TEMP CONTROLLER OPERATIONAL TEST & FOUND WORKING PROPERLY NO DEFECTTS NOTED AT THIS TIME IAW CRJ MM 30-41-06