What was found
#4 LOWER SERVICE DOOR BEAM CRACKED IN RADIUS AT I/B SIDE OF BEAM NEXT TO FASTENER ROW. / [01] REMOVED FSD PER AMM 52-41-00-000-801.; [02] OK TO INSTALL FWD SERVICE DOOR; [03] INSTALLED FWD SERVICE DOOR PER AMM 52-41-00-400-801 STEPS 3. F. (1)-(6); [04] VERIFIED INSTALLED FWD SERVICE DOOR PER AMM 52-41-00-400-801 STEPS 3. F. (1)-(6); [05] ADJUSTED FORWARD SERVICE DOOR PER AMM 52-41-00-820-801 STEP 2.G(1-3); 2.H(1A-B); 2.I(1A-B); 2.J(1A-C); 2.K(1A-B); 2.L(1B)(4A-D); 2.M(1B)(3A-C); 2.N(1A-B); 2.O(1A-B); 2.P(1A-B); 2.Q(1A-D); 2.R(1A-D); 2.S(1A-B) NO OTHER ADJUSTMENT NEEDED <BR>PERFORMED FORWARD SERVICE DOOR INDICATION SENSOR ADJUSTMENT PER AMM 52-71-11-820-801 OPS CHECK GOOD <BR>USED DIGITAL CALIPER <BR>ID:PER2059<BR>S/N:C011903743M<BR>DATE:10/2020<BR>DUE:10/2021; [06] PERFORMED FORWARD SERVICE DOOR SYSTEM TEST PER AMM 52-41-00-700-801 <BR>USED TORQUE WRENCH <BR>ID:ATS2321<BR>SN:0119121014<BR>DATE:05/2021<BR>DUE:05/2022; [07] UPDATED MEASUREMENTS AND INSTALLED DOOR IN MXI.;