What was found
LAV SERVICE DOOR HAS CORROSION AROUND BONDING JUMPER STUD ON THE INTERNAL SIDE OF DOOR SIDE ; / [01] EVALUATED CORROSION ON LAV SERVICE DOOR; FOUND 0.020 REMOVED FROM ORIG 0.060 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 52-40-01-1A-4 USING MICROMETER P/N 4566A S/N UNKNOWN; [02] VERIFIED CORROSION ON LAV SERVICE DOOR; FOUND 0.020 REMOVED FROM ORIG 0.060 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 52-40-01-1A-4 USING MICROMETER P/N 4566A S/N UNKNOWN; [03] REMOVED AND REPLACED LAV SERVICE DOOR PER AMM 52-49-09-000-801 AND 52-49-09-400-801. PERFORMED BOND CHECK PER STEP 3.C.(1).(E).1) WITH BOND METER; TOOL ID: ATS1256; S/N: DC003960. BOND CHECK GOOD. PERFORMED PANEL FIT CHECK PER AMM 52-49-09-000-802; FIT CHECK GOOD.; [04] VERIFIED REMOVED AND REPLACED LAV SERVICE DOOR PER AMM 52-49-09-000-801 AND 52-49-09-400-801. PERFORMED BOND CHECK PER STEP 3.C.(1).(E).1) WITH BOND METER; TOOL ID: ATS1256; S/N: DC003960. BOND CHECK GOOD. PERFORMED PANEL FIT CHECK PER AMM 52-49-09-000-802; FIT CHECK GOOD.