What was found
CRACK ON FWD CARGO BAY FRAME TO INTERCOSTAL ATTACH ANGLE AT LBL 23 BS 400. ; / [01] DAMAGE FOUND ON INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS400 LBL23; FOUND TO BE OUT OF LIMITS DUE TO O LIMITS ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERIFIED CORRECTIVE ACTION ENTRY 1.; [03] REMOVED FWD CARGO BAY FRAME TO INTERCOSTAL ATTACH ANGLE CRACKED AT LBL 23 BS 400 IAW SRM 51-40-02.; [04] RECEIVED NEW ANGLE WITH ITEM#143A7502U155; LOT#1478785-5; LOCATED AND DRILLED NEW ANGLE IAW SRM 51-40-05 AND DWG#143A7505. OK TO INSTALL.; [05] VERIFIED CORRECTIVE ACTION ENTRIES 3. AND 4.<BR><BR>OK TO INSTALL NEW ANGLE; [06] INSTALLED NEW FCB FRAME TO INTERCOSTAL ATTACH ANGLE BS400 LBL23 IAW