What was found
ELONGATED HOLE LOC. ON LEADING EDGE RIB STA 142.45 OF LEADING EDGE PANEL 331B LT HORIZONTAL STABILIZER 2024-357668<[01] REPLACED RIB LOC LEADING EDGE STA 142.45 OF LEADING EDGE PANEL 331B LT HORIZONTAL STABILIZER IAW B737-700 SRM 51-10-02. STEP 9 AND SRM 51-40-02 DWG 186A1001 SHEET 10 REV:A AND IT WAS RESOLVED ON THE OTHER TASK CARD TTG8Q00TQ6RA. SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED RIB LOC LEADING EDGE STA 142.45 OF LEADING EDGE PANEL 331B LT HORIZONTAL STABILIZER IAW B737-700 SRM 51-10-02. STEP 9 AND SRM 51-40-02 DWG 186A1001 SHEET 10 REV:A AND IT WAS RESOLVED ON THE OTHER TASK CARD TTG8Q00TQ6RA. SEE INDIVIDUAL SIGN OFF BELOW