What was found
LE FLAPS TRANSIT REMAINING ILLUMINATED WITH FLAPS 5 EXTENDED<[01] PERFORMED FSEU BITE NO FAULTS FOUND; OK TO CONTINUE PER MEL 27-4-02 SP1;[02] 02 - INSPECTED PER [AMM 27-88-00-201-NG (LEADING EDGE FLAP AND SLAT POSITION INDICATING SYSTEM - MAINTENANCE PRACTICES - PERMANENT)] INSPECTED AND OPERATED FLAPS LE SYSTEM . NO TRANSIT LIGHT REAINS ON AT FLAPS 5 . FSCU SHOWS NO FAULTS OR FAULT HISTORY. ALL SENSORS SHOW NORMAL NEAR/FAR INDICATIONS . NO DEFECTS NOTED. I/A/W AMM 27-88-00 THIS CLEARS AUTH# 219627 RE-INSTALLED LAMPS IN INDICATOR.