What was found
CRACK FRONT SPAR INSPAR RIB LOCATED STAB STA 129.50 AND 27 INCH RT HORIZONTAL STAB 2024-672236<[01] TOOL USED ET EQUIPMENT: P/N: NORTEC 600D; S/N: 60007161486; CAL DUE DATE: 06-SEP-25;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 210136503; DUE DATE: 24-JUL-25.;[03] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 210136503; DUE DATE: 24-JUL-25.;[04] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 23-JAN-25; TEMPERATURE; CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 23-JAN-25.;[05] PERFORMED PERMANENT REPAIR ON FRONT SPAR INSPAR RIB LOCATED STAB STA 129.50 AND 27 INCH RT HORIZONTAL STAB IAW IAW B737-700 SRM 55-10-09-2R-5 REPAIR 5. SEE INDIVIDUAL SIGN OFFS BELOW.;[06] PERFORMED PERMANENT REPAIR ON FRONT SPAR INSPAR RIB LOCATED STAB STA 129.50 AND 27 INCH RT HORIZONTAL STAB IAW IAW B737-700 SRM 55-10-09-2R-5 REPAIR 5. SEE INDIVIDUAL SIGN OFFS BELOW.<BR>CERTIFIED AS RII