What was found
EGPR SURROUND DOUBLER IS CRACKED BS 233, WL 175, 8 INCHES ABOVE S24R. CRACK WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-5. TRIMMED OUT THE DAMAGED AREA OF THE EGPR SURROUND DOUBLER IAW SRM 53-10-15-2R-4, REPAIR 4, PARA 4(C). FABRICATED REPAIR PARTS IAW SRM 53-10-15-2R-4, REPAIR 4, PARA 4(E-L) AND INSTALLED ALL REPAIR PARTS AT EGPR SURROUND DOUBLER BS 233, WL 175, 8 INCHES ABOVE S24R IAW SRM 51-40-02-0G-0, & SRM 53-10-15-2R-4, REPAIR 4 PARA 4(M).