Service difficulty report · Controller · Cndair CL6002D24

Difficulty date
May 18, 2021
Submitted
May 19, 2021
Operation
Air carrier
Aircraft
N809SK
Make and model
Cndair CL6002D24
Aircraft serial
15086
Aircraft time
36,967 hours, 23,614 cycles
Part
Controller
Condition
Failed
Location
R1 Window
Stage of operation
DE
How discovered
O
Nature of condition
J, B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING DESCENT, HEARD A LOUD POP FROM THE RT FLIGHT DECK WINDOW. NEXT, RECEIVED A RT WINDOW HEAT CAUTION MESSAGE. FLIGHT DECK FILLED WITH AN ACRID BURNING ODOR, NO SMOKE WAS VISIBLE. ODOR DISSIPATED RAPIDLY. SUSPECT THAT THE RT WINDOW FAILED. (FLIGHT 3812) R & R RT SIDE WINDOW TEMPERATURE CONTROLLER IAW AMM 30-41-06. NO FIX. R & R RT SIDE WINDOW IAW AMM 56-12-01 & MIP 56-220-1000. LEAK CHECKED GOOD. PERFORMED OPS CHECK OF RT WINDOW TEMPERATURE CONTROLLER IAW AMM 30-41-06. OPS CHECKED GOOD. NO EVIDENCE OF LIGHTNING STRIKE NOTED. REFERENCE AML 639933 FOR MAINTENANCE PERFORMED AND PARTS INFORMATION OF REMOVAL/REPLACEMENT OF THE RT SIDE WINDOW TEMPERATURE CONTROLLER.