What was found
RH ELEVATOR PCU TO ELEVATOR BOLTS DONT LINE UP WITH COTTER PIN HOLE WITHIN REQUIRED TOURQE VALUE AND NEED REPLACED WITH NEW HARDWARE (C CHECK RO 01-05-2022) RH ELEVATOR PCU TO ELEVATOR HARDWARE WAS REPLACED AS REQUIRED IAW CRJ 700 AMM 27-33-01-000-400-801-A01 AND TASK CARDS 27-320-1003-SKY. SEE ATTACHED CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.