What was found
DURING AUDIT OF 1C TASK CARD 53-230-504(DETAILED INSPECTION OF THE GALLEY SERVICE DOOR (FORWARD) EXTERNALSURROUND STRUCTURE AND FITTINGS - FS319.70 TO FS349.00, STGR9R TOSTGR18R (EES)) FOUND POSSIBLE CORROSION THE LOWER INBOARD SIDE OF THE SVC DR SEAL STRIKER. (C-CHECK RO 07/18/2025)REMOVED AND REPLACED SEAL STRIKER P/N SH670-31412-3 REF SRM 51-42-06-001-001-A01 & DWG SH670-31950 REV YPERFORMED PRESSURE CHECK OF SERVICE DOOR SEAL AND STRIKER REF AMM 21-31-00-910-801-A01. NO LEAKS NOTED AT THIS TIME. COMPLIED WITH TASK CARD 51-900-1002-SKY