What was found
CORRODED NUTPLATE ON FLOOR BOARD LANDING JUST AFT OF FS 559.00+80 ON RBL 9. REMOVED AND REPLACED UPPER FLOOR BEAM (FLOORBOARD LANDING/SEAT TRACK MOUNT), SPLICE CHANNELS, SUPPORTS & REMOVED AND REINSTALLED 4 INTEGRATED CROSSBEAM WEBS, INTERCOSTAL CLIPS/BRACKETS BETWEEN FS559.00+64 TO FS 574.00 AT RBL 9.00 IN REFERENCE TO SRM 51-42-06, 51-42-21, 53-00-43 AND REO 601R-53-00-027, REV. D, DATED 26-NOV-2009 AND REO 601R-53-51-741, REV.--, DATED 2026-05-28. ALL NDT'S COMPLIED WITH NO DEFECTS FOUND AT THIS TIME. COMPLETED TASK CARD 51-900-1003-SKY. REF. CP 32194801 FOR THE CROSSBEAM FREEZE PLUG INSTALLATION. REFERENCE CHILD CP 32270652 FOR EDDY CURRENT.