Service difficulty report · Sensor · Emb ERJ170200LL

Difficulty date
May 28, 2026
Submitted
May 29, 2026
Operation
Air carrier
Aircraft
N624UX
Make and model
Emb ERJ170200LL
Aircraft serial
17000831
Aircraft time
13,369 hours, 9,069 cycles
Part
Sensor
Part number
10015411
Part serial
2503F278
Condition
Faulted
Location
Slat Temp
Part time
23 hours, 16 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

A-I WING 1 LEAK WARNING IN CLIMB. RAN QRH AND MESSAGE CLEARED. SYNOPTIC PAGE SHOWED LEFT WING ANTI ICE AMBER, 15 DEGREES C. WING ANTI ICE WAS OFF AT TIME OF MESSAGE.C: MEL 30-11-0 DEFERRED DUE TO HISTORY AND RECENT REPLACEMENT OF SLAT 2 TEMP SENSOR.CAT C DUE 07 JUN 26 (FLIGHT 5208 - FILED OPEN)MAY 28, 2026 STATION: GJT--TROUBLESHOT IN REFERENCE TO FIM 30-11-02. INTERROGATED CMC AND FOUND MULTIPLE HITS ON FAULT CODE 30115009AM1 INDICATING THE LH SLAT OUTBOARD TEMP SENSOR FAILING ON BOTH CHANNELS ONE AND TWO. PILOT WRITE UP STATES WING ANTI-ICE WAS OFF AT TIME OF MESSAGE. SUSPECT FAULTY TEMP SENSOR. REMOVED AND REPLACED THE LH SLAT OUTBOARD TEMP SENSOR IN REFERENCE TO AMM 30-11-02. OPS CHKD GOOD.