What was found
LEFT TRU BAY FLOOR ANGLE AT BS 193 BENT AND GOUGED. REPLACED DAMAGED THE LT TRU BAY FLOOR ANGLE WITH NEW FABRICATED ANGLE IAW SRM 51-42-06, & DWG 600-33101, REV R. COMPLIED WITH SKY CARD 51-900-1003-SKY. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT TRU BAY FLOOR ANGLE AT BS 193 BENT AND GOUGED. REPLACED DAMAGED THE LT TRU BAY FLOOR ANGLE WITH NEW FABRICATED ANGLE IAW SRM 51-42-06, & DWG 600-33101, REV R. COMPLIED WITH SKY CARD 51-900-1003-SKY. MAJOR REPAIR.